nixos-config/hosts/defiant/services/monitoring/snmp-exporter-conf.yml

1662 lines
55 KiB
YAML
Raw Normal View History

modules:
synology:
max_repetitions: 22
walk:
- 1.3.6.1.4.1.2021.10.1.2
- 1.3.6.1.4.1.2021.10.1.5
- 1.3.6.1.4.1.2021.4
- 1.3.6.1.4.1.6574.1
- 1.3.6.1.4.1.6574.101
- 1.3.6.1.4.1.6574.102
- 1.3.6.1.4.1.6574.104
- 1.3.6.1.4.1.6574.2
- 1.3.6.1.4.1.6574.3
- 1.3.6.1.4.1.6574.4
- 1.3.6.1.4.1.6574.5
- 1.3.6.1.4.1.6574.6
get:
- 1.3.6.1.4.1.2021.11.10.0
- 1.3.6.1.4.1.2021.11.11.0
- 1.3.6.1.4.1.2021.11.9.0
metrics:
- name: laNames
oid: 1.3.6.1.4.1.2021.10.1.2
type: DisplayString
help: The list of loadave names we're watching. - 1.3.6.1.4.1.2021.10.1.2
indexes:
- labelname: laIndex
type: gauge
lookups:
- labels:
- laIndex
labelname: laNames
oid: 1.3.6.1.4.1.2021.10.1.2
type: DisplayString
- labels: []
labelname: laIndex
- name: laLoadInt
oid: 1.3.6.1.4.1.2021.10.1.5
type: gauge
help: The 1,5 and 15 minute load averages as an integer - 1.3.6.1.4.1.2021.10.1.5
indexes:
- labelname: laIndex
type: gauge
lookups:
- labels:
- laIndex
labelname: laNames
oid: 1.3.6.1.4.1.2021.10.1.2
type: DisplayString
- labels: []
labelname: laIndex
- name: ssCpuSystem
oid: 1.3.6.1.4.1.2021.11.10
type: gauge
help: The percentage of CPU time spent processing system-level code, calculated
over the last minute - 1.3.6.1.4.1.2021.11.10
- name: ssCpuIdle
oid: 1.3.6.1.4.1.2021.11.11
type: gauge
help: The percentage of processor time spent idle, calculated over the last
minute - 1.3.6.1.4.1.2021.11.11
- name: ssCpuUser
oid: 1.3.6.1.4.1.2021.11.9
type: gauge
help: The percentage of CPU time spent processing user-level code, calculated
over the last minute - 1.3.6.1.4.1.2021.11.9
- name: memIndex
oid: 1.3.6.1.4.1.2021.4.1
type: gauge
help: Bogus Index - 1.3.6.1.4.1.2021.4.1
- name: memErrorName
oid: 1.3.6.1.4.1.2021.4.2
type: DisplayString
help: Bogus Name - 1.3.6.1.4.1.2021.4.2
- name: memTotalSwap
oid: 1.3.6.1.4.1.2021.4.3
type: gauge
help: The total amount of swap space configured for this host. - 1.3.6.1.4.1.2021.4.3
- name: memAvailSwap
oid: 1.3.6.1.4.1.2021.4.4
type: gauge
help: The amount of swap space currently unused or available. - 1.3.6.1.4.1.2021.4.4
- name: memTotalReal
oid: 1.3.6.1.4.1.2021.4.5
type: gauge
help: The total amount of real/physical memory installed on this host. - 1.3.6.1.4.1.2021.4.5
- name: memAvailReal
oid: 1.3.6.1.4.1.2021.4.6
type: gauge
help: The amount of real/physical memory currently unused or available. - 1.3.6.1.4.1.2021.4.6
- name: memTotalSwapTXT
oid: 1.3.6.1.4.1.2021.4.7
type: gauge
help: The total amount of swap space or virtual memory allocated for text pages
on this host - 1.3.6.1.4.1.2021.4.7
- name: memAvailSwapTXT
oid: 1.3.6.1.4.1.2021.4.8
type: gauge
help: The amount of swap space or virtual memory currently being used by text
pages on this host - 1.3.6.1.4.1.2021.4.8
- name: memTotalRealTXT
oid: 1.3.6.1.4.1.2021.4.9
type: gauge
help: The total amount of real/physical memory allocated for text pages on this
host - 1.3.6.1.4.1.2021.4.9
- name: memAvailRealTXT
oid: 1.3.6.1.4.1.2021.4.10
type: gauge
help: The amount of real/physical memory currently being used by text pages
on this host - 1.3.6.1.4.1.2021.4.10
- name: memTotalFree
oid: 1.3.6.1.4.1.2021.4.11
type: gauge
help: The total amount of memory free or available for use on this host - 1.3.6.1.4.1.2021.4.11
- name: memMinimumSwap
oid: 1.3.6.1.4.1.2021.4.12
type: gauge
help: The minimum amount of swap space expected to be kept free or available
during normal operation of this host - 1.3.6.1.4.1.2021.4.12
- name: memShared
oid: 1.3.6.1.4.1.2021.4.13
type: gauge
help: The total amount of real or virtual memory currently allocated for use
as shared memory - 1.3.6.1.4.1.2021.4.13
- name: memBuffer
oid: 1.3.6.1.4.1.2021.4.14
type: gauge
help: The total amount of real or virtual memory currently allocated for use
as memory buffers - 1.3.6.1.4.1.2021.4.14
- name: memCached
oid: 1.3.6.1.4.1.2021.4.15
type: gauge
help: The total amount of real or virtual memory currently allocated for use
as cached memory - 1.3.6.1.4.1.2021.4.15
- name: memUsedSwapTXT
oid: 1.3.6.1.4.1.2021.4.16
type: gauge
help: The amount of swap space or virtual memory currently being used by text
pages on this host - 1.3.6.1.4.1.2021.4.16
- name: memUsedRealTXT
oid: 1.3.6.1.4.1.2021.4.17
type: gauge
help: The amount of real/physical memory currently being used by text pages
on this host - 1.3.6.1.4.1.2021.4.17
- name: memTotalSwapX
oid: 1.3.6.1.4.1.2021.4.18
type: counter
help: The total amount of swap space configured for this host. - 1.3.6.1.4.1.2021.4.18
- name: memAvailSwapX
oid: 1.3.6.1.4.1.2021.4.19
type: counter
help: The amount of swap space currently unused or available. - 1.3.6.1.4.1.2021.4.19
- name: memTotalRealX
oid: 1.3.6.1.4.1.2021.4.20
type: counter
help: The total amount of real/physical memory installed on this host. - 1.3.6.1.4.1.2021.4.20
- name: memAvailRealX
oid: 1.3.6.1.4.1.2021.4.21
type: counter
help: The amount of real/physical memory currently unused or available. - 1.3.6.1.4.1.2021.4.21
- name: memTotalFreeX
oid: 1.3.6.1.4.1.2021.4.22
type: counter
help: The total amount of memory free or available for use on this host - 1.3.6.1.4.1.2021.4.22
- name: memMinimumSwapX
oid: 1.3.6.1.4.1.2021.4.23
type: counter
help: The minimum amount of swap space expected to be kept free or available
during normal operation of this host - 1.3.6.1.4.1.2021.4.23
- name: memSharedX
oid: 1.3.6.1.4.1.2021.4.24
type: counter
help: The total amount of real or virtual memory currently allocated for use
as shared memory - 1.3.6.1.4.1.2021.4.24
- name: memBufferX
oid: 1.3.6.1.4.1.2021.4.25
type: counter
help: The total amount of real or virtual memory currently allocated for use
as memory buffers - 1.3.6.1.4.1.2021.4.25
- name: memCachedX
oid: 1.3.6.1.4.1.2021.4.26
type: counter
help: The total amount of real or virtual memory currently allocated for use
as cached memory - 1.3.6.1.4.1.2021.4.26
- name: memSwapError
oid: 1.3.6.1.4.1.2021.4.100
type: gauge
help: Indicates whether the amount of available swap space (as reported by 'memAvailSwap(4)'),
is less than the desired minimum (specified by 'memMinimumSwap(12)'). - 1.3.6.1.4.1.2021.4.100
enum_values:
0: noError
1: error
- name: memSwapErrorMsg
oid: 1.3.6.1.4.1.2021.4.101
type: DisplayString
help: Describes whether the amount of available swap space (as reported by 'memAvailSwap(4)'),
is less than the desired minimum (specified by 'memMinimumSwap(12)'). - 1.3.6.1.4.1.2021.4.101
- name: systemStatus
oid: 1.3.6.1.4.1.6574.1.1
type: gauge
help: Synology system status Each meanings of status represented describe below
- 1.3.6.1.4.1.6574.1.1
- name: temperature
oid: 1.3.6.1.4.1.6574.1.2
type: gauge
help: Synology system temperature The temperature of Disk Station uses Celsius
degree. - 1.3.6.1.4.1.6574.1.2
- name: powerStatus
oid: 1.3.6.1.4.1.6574.1.3
type: gauge
help: Synology power status Each meanings of status represented describe below
- 1.3.6.1.4.1.6574.1.3
- name: systemFanStatus
oid: 1.3.6.1.4.1.6574.1.4.1
type: gauge
help: Synology system fan status Each meanings of status represented describe
below - 1.3.6.1.4.1.6574.1.4.1
- name: cpuFanStatus
oid: 1.3.6.1.4.1.6574.1.4.2
type: gauge
help: Synology cpu fan status Each meanings of status represented describe below
- 1.3.6.1.4.1.6574.1.4.2
- name: modelName
oid: 1.3.6.1.4.1.6574.1.5.1
type: DisplayString
help: The Model name of this NAS - 1.3.6.1.4.1.6574.1.5.1
- name: serialNumber
oid: 1.3.6.1.4.1.6574.1.5.2
type: OctetString
help: The serial number of this NAS - 1.3.6.1.4.1.6574.1.5.2
- name: version
oid: 1.3.6.1.4.1.6574.1.5.3
type: OctetString
help: The version of this DSM - 1.3.6.1.4.1.6574.1.5.3
- name: upgradeAvailable
oid: 1.3.6.1.4.1.6574.1.5.4
type: gauge
help: This oid is for checking whether there is a latest DSM can be upgraded
- 1.3.6.1.4.1.6574.1.5.4
- name: controllerNumber
oid: 1.3.6.1.4.1.6574.1.6
type: gauge
help: Synology system controller number Controller A(0) Controller B(1) - 1.3.6.1.4.1.6574.1.6
- name: storageIOIndex
oid: 1.3.6.1.4.1.6574.101.1.1.1
type: gauge
help: Reference index for each observed device. - 1.3.6.1.4.1.6574.101.1.1.1
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.101.1.1.2
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIONRead
oid: 1.3.6.1.4.1.6574.101.1.1.3
type: counter
help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.3
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIONWritten
oid: 1.3.6.1.4.1.6574.101.1.1.4
type: counter
help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.4
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIOReads
oid: 1.3.6.1.4.1.6574.101.1.1.5
type: counter
help: The number of read accesses from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.5
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIOWrites
oid: 1.3.6.1.4.1.6574.101.1.1.6
type: counter
help: The number of write accesses to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.6
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIOLA
oid: 1.3.6.1.4.1.6574.101.1.1.8
type: gauge
help: The load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.8
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIOLA1
oid: 1.3.6.1.4.1.6574.101.1.1.9
type: gauge
help: The 1 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.9
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIOLA5
oid: 1.3.6.1.4.1.6574.101.1.1.10
type: gauge
help: The 5 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.10
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIOLA15
oid: 1.3.6.1.4.1.6574.101.1.1.11
type: gauge
help: The 15 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.11
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIONReadX
oid: 1.3.6.1.4.1.6574.101.1.1.12
type: counter
help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.12
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIONWrittenX
oid: 1.3.6.1.4.1.6574.101.1.1.13
type: counter
help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.13
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: storageIODeviceSerial
oid: 1.3.6.1.4.1.6574.101.1.1.14
type: DisplayString
help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.101.1.1.14
indexes:
- labelname: storageIOIndex
type: gauge
lookups:
- labels:
- storageIOIndex
labelname: storageIODevice
oid: 1.3.6.1.4.1.6574.101.1.1.2
type: DisplayString
- labels: []
labelname: storageIOIndex
- name: spaceIOIndex
oid: 1.3.6.1.4.1.6574.102.1.1.1
type: gauge
help: Reference index for each observed device. - 1.3.6.1.4.1.6574.102.1.1.1
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.102.1.1.2
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIONRead
oid: 1.3.6.1.4.1.6574.102.1.1.3
type: counter
help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.3
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIONWritten
oid: 1.3.6.1.4.1.6574.102.1.1.4
type: counter
help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.4
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIOReads
oid: 1.3.6.1.4.1.6574.102.1.1.5
type: counter
help: The number of read accesses from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.5
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIOWrites
oid: 1.3.6.1.4.1.6574.102.1.1.6
type: counter
help: The number of write accesses to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.6
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIOLA
oid: 1.3.6.1.4.1.6574.102.1.1.8
type: gauge
help: The load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.8
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIOLA1
oid: 1.3.6.1.4.1.6574.102.1.1.9
type: gauge
help: The 1 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.9
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIOLA5
oid: 1.3.6.1.4.1.6574.102.1.1.10
type: gauge
help: The 5 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.10
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIOLA15
oid: 1.3.6.1.4.1.6574.102.1.1.11
type: gauge
help: The 15 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.11
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIONReadX
oid: 1.3.6.1.4.1.6574.102.1.1.12
type: counter
help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.12
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceIONWrittenX
oid: 1.3.6.1.4.1.6574.102.1.1.13
type: counter
help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.13
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: spaceUUID
oid: 1.3.6.1.4.1.6574.102.1.1.14
type: DisplayString
help: The uuid of space. - 1.3.6.1.4.1.6574.102.1.1.14
indexes:
- labelname: spaceIOIndex
type: gauge
lookups:
- labels:
- spaceIOIndex
labelname: spaceIODevice
oid: 1.3.6.1.4.1.6574.102.1.1.2
type: DisplayString
- labels: []
labelname: spaceIOIndex
- name: iSCSILUNInfoIndex
oid: 1.3.6.1.4.1.6574.104.1.1.1
type: gauge
help: LUN info index - 1.3.6.1.4.1.6574.104.1.1.1
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNUUID
oid: 1.3.6.1.4.1.6574.104.1.1.2
type: OctetString
help: LUN uuid - 1.3.6.1.4.1.6574.104.1.1.2
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNName
oid: 1.3.6.1.4.1.6574.104.1.1.3
type: OctetString
help: LUN name - 1.3.6.1.4.1.6574.104.1.1.3
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNThroughputReadHigh
oid: 1.3.6.1.4.1.6574.104.1.1.4
type: gauge
help: LUN read throughput over 32 bits part - 1.3.6.1.4.1.6574.104.1.1.4
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNThroughputReadLow
oid: 1.3.6.1.4.1.6574.104.1.1.5
type: gauge
help: LUN read throughput in unsigned 32 bit - 1.3.6.1.4.1.6574.104.1.1.5
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNThroughputWriteHigh
oid: 1.3.6.1.4.1.6574.104.1.1.6
type: gauge
help: LUN write throughput over 32 bits part - 1.3.6.1.4.1.6574.104.1.1.6
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNThroughputWriteLow
oid: 1.3.6.1.4.1.6574.104.1.1.7
type: gauge
help: LUN write throughput in unsigned 32 bit - 1.3.6.1.4.1.6574.104.1.1.7
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNIopsRead
oid: 1.3.6.1.4.1.6574.104.1.1.8
type: gauge
help: LUN read iops - 1.3.6.1.4.1.6574.104.1.1.8
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNIopsWrite
oid: 1.3.6.1.4.1.6574.104.1.1.9
type: gauge
help: LUN write iops - 1.3.6.1.4.1.6574.104.1.1.9
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNDiskLatencyRead
oid: 1.3.6.1.4.1.6574.104.1.1.10
type: gauge
help: LUN disk latency when reading - 1.3.6.1.4.1.6574.104.1.1.10
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNDiskLatencyWrite
oid: 1.3.6.1.4.1.6574.104.1.1.11
type: gauge
help: LUN disk latency when writing - 1.3.6.1.4.1.6574.104.1.1.11
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNNetworkLatencyTx
oid: 1.3.6.1.4.1.6574.104.1.1.12
type: gauge
help: LUN transfer data network latency - 1.3.6.1.4.1.6574.104.1.1.12
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNNetworkLatencyRx
oid: 1.3.6.1.4.1.6574.104.1.1.13
type: gauge
help: LUN receive data network latency - 1.3.6.1.4.1.6574.104.1.1.13
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNIoSizeRead
oid: 1.3.6.1.4.1.6574.104.1.1.14
type: gauge
help: LUN average io size when reading - 1.3.6.1.4.1.6574.104.1.1.14
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNIoSizeWrite
oid: 1.3.6.1.4.1.6574.104.1.1.15
type: gauge
help: LUN average io size when writing - 1.3.6.1.4.1.6574.104.1.1.15
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNQueueDepth
oid: 1.3.6.1.4.1.6574.104.1.1.16
type: gauge
help: Num of iSCSI commands in LUN queue - 1.3.6.1.4.1.6574.104.1.1.16
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNType
oid: 1.3.6.1.4.1.6574.104.1.1.17
type: OctetString
help: LUN type - 1.3.6.1.4.1.6574.104.1.1.17
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNDiskLatencyAvg
oid: 1.3.6.1.4.1.6574.104.1.1.18
type: gauge
help: Average latency of LUN disk - 1.3.6.1.4.1.6574.104.1.1.18
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: iSCSILUNThinProvisionVolFreeMBs
oid: 1.3.6.1.4.1.6574.104.1.1.19
type: gauge
help: Free space(MB) of thin provisioning lun's volume - 1.3.6.1.4.1.6574.104.1.1.19
indexes:
- labelname: iSCSILUNInfoIndex
type: gauge
- name: diskIndex
oid: 1.3.6.1.4.1.6574.2.1.1.1
type: gauge
help: The index of disk table - 1.3.6.1.4.1.6574.2.1.1.1
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
help: Synology disk ID The ID of disk is assigned by disk Station. - 1.3.6.1.4.1.6574.2.1.1.2
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskModel
oid: 1.3.6.1.4.1.6574.2.1.1.3
type: DisplayString
help: Synology disk model name The disk model name will be showed here. - 1.3.6.1.4.1.6574.2.1.1.3
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskType
oid: 1.3.6.1.4.1.6574.2.1.1.4
type: DisplayString
help: Synology disk type The type of disk will be showed here, including SATA,
SSD and so on. - 1.3.6.1.4.1.6574.2.1.1.4
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskStatus
oid: 1.3.6.1.4.1.6574.2.1.1.5
type: gauge
help: Synology disk status Each meanings of status represented describe below
- 1.3.6.1.4.1.6574.2.1.1.5
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskTemperature
oid: 1.3.6.1.4.1.6574.2.1.1.6
type: gauge
help: Synology disk temperature The temperature of each disk uses Celsius degree.
- 1.3.6.1.4.1.6574.2.1.1.6
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskRole
oid: 1.3.6.1.4.1.6574.2.1.1.7
type: OctetString
help: Synology disk role The role of the disk in system - 1.3.6.1.4.1.6574.2.1.1.7
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskRetry
oid: 1.3.6.1.4.1.6574.2.1.1.8
type: gauge
help: Synology disk retry count The count of each disk connection retries. -
1.3.6.1.4.1.6574.2.1.1.8
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskBadSector
oid: 1.3.6.1.4.1.6574.2.1.1.9
type: gauge
help: Synology disk bad sector count The count of each disk I/O bad sector.
- 1.3.6.1.4.1.6574.2.1.1.9
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskIdentifyFail
oid: 1.3.6.1.4.1.6574.2.1.1.10
type: gauge
help: Synology disk identify fail count The count of each disk identify fails.
- 1.3.6.1.4.1.6574.2.1.1.10
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskRemainLife
oid: 1.3.6.1.4.1.6574.2.1.1.11
type: gauge
help: Synology disk remainLife The estimate remain life of each disk. - 1.3.6.1.4.1.6574.2.1.1.11
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskName
oid: 1.3.6.1.4.1.6574.2.1.1.12
type: OctetString
help: Synology disk name The name of disk which align to storage manager. -
1.3.6.1.4.1.6574.2.1.1.12
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: diskHealthStatus
oid: 1.3.6.1.4.1.6574.2.1.1.13
type: gauge
help: Synology disk health status Each meanings of status represented describe
below - 1.3.6.1.4.1.6574.2.1.1.13
indexes:
- labelname: diskIndex
type: gauge
lookups:
- labels:
- diskIndex
labelname: diskID
oid: 1.3.6.1.4.1.6574.2.1.1.2
type: OctetString
- labels: []
labelname: diskIndex
- name: raidIndex
oid: 1.3.6.1.4.1.6574.3.1.1.1
type: gauge
help: The index of raid table - 1.3.6.1.4.1.6574.3.1.1.1
indexes:
- labelname: raidIndex
type: gauge
lookups:
- labels:
- raidIndex
labelname: raidName
oid: 1.3.6.1.4.1.6574.3.1.1.2
type: DisplayString
- labels: []
labelname: raidIndex
- name: raidName
oid: 1.3.6.1.4.1.6574.3.1.1.2
type: DisplayString
help: Synology raid name The name of each raid will be showed here. - 1.3.6.1.4.1.6574.3.1.1.2
indexes:
- labelname: raidIndex
type: gauge
lookups:
- labels:
- raidIndex
labelname: raidName
oid: 1.3.6.1.4.1.6574.3.1.1.2
type: DisplayString
- labels: []
labelname: raidIndex
- name: raidStatus
oid: 1.3.6.1.4.1.6574.3.1.1.3
type: gauge
help: Synology Raid status Each meanings of status represented describe below
- 1.3.6.1.4.1.6574.3.1.1.3
indexes:
- labelname: raidIndex
type: gauge
lookups:
- labels:
- raidIndex
labelname: raidName
oid: 1.3.6.1.4.1.6574.3.1.1.2
type: DisplayString
- labels: []
labelname: raidIndex
- name: raidFreeSize
oid: 1.3.6.1.4.1.6574.3.1.1.4
type: gauge
help: Synology raid freesize Free space in bytes. - 1.3.6.1.4.1.6574.3.1.1.4
indexes:
- labelname: raidIndex
type: gauge
lookups:
- labels:
- raidIndex
labelname: raidName
oid: 1.3.6.1.4.1.6574.3.1.1.2
type: DisplayString
- labels: []
labelname: raidIndex
- name: raidTotalSize
oid: 1.3.6.1.4.1.6574.3.1.1.5
type: gauge
help: Synology raid totalsize Total space in bytes. - 1.3.6.1.4.1.6574.3.1.1.5
indexes:
- labelname: raidIndex
type: gauge
lookups:
- labels:
- raidIndex
labelname: raidName
oid: 1.3.6.1.4.1.6574.3.1.1.2
type: DisplayString
- labels: []
labelname: raidIndex
- name: raidHotspareCnt
oid: 1.3.6.1.4.1.6574.3.1.1.6
type: gauge
help: Synology raid hotspare Total hotspare disks count - 1.3.6.1.4.1.6574.3.1.1.6
indexes:
- labelname: raidIndex
type: gauge
lookups:
- labels:
- raidIndex
labelname: raidName
oid: 1.3.6.1.4.1.6574.3.1.1.2
type: DisplayString
- labels: []
labelname: raidIndex
- name: upsDeviceModel
oid: 1.3.6.1.4.1.6574.4.1.1
type: DisplayString
help: Device model - 1.3.6.1.4.1.6574.4.1.1
- name: upsDeviceManufacturer
oid: 1.3.6.1.4.1.6574.4.1.2
type: DisplayString
help: Device manufacturer - 1.3.6.1.4.1.6574.4.1.2
- name: upsDeviceSerial
oid: 1.3.6.1.4.1.6574.4.1.3
type: DisplayString
help: Device serial number. - 1.3.6.1.4.1.6574.4.1.3
- name: upsDeviceType
oid: 1.3.6.1.4.1.6574.4.1.4
type: DisplayString
help: Device type (ups, pdu, scd, psu) - 1.3.6.1.4.1.6574.4.1.4
- name: upsDeviceDescription
oid: 1.3.6.1.4.1.6574.4.1.5
type: DisplayString
help: Device description. - 1.3.6.1.4.1.6574.4.1.5
- name: upsDeviceContact
oid: 1.3.6.1.4.1.6574.4.1.6
type: DisplayString
help: Device administrator name. - 1.3.6.1.4.1.6574.4.1.6
- name: upsDeviceLocation
oid: 1.3.6.1.4.1.6574.4.1.7
type: DisplayString
help: Device physical location. - 1.3.6.1.4.1.6574.4.1.7
- name: upsDevicePart
oid: 1.3.6.1.4.1.6574.4.1.8
type: DisplayString
help: Device part number. - 1.3.6.1.4.1.6574.4.1.8
- name: upsDeviceMACAddr
oid: 1.3.6.1.4.1.6574.4.1.9
type: DisplayString
help: Physical network address of the device. - 1.3.6.1.4.1.6574.4.1.9
- name: upsInfoStatus
oid: 1.3.6.1.4.1.6574.4.2.1
type: DisplayString
help: UPS status. - 1.3.6.1.4.1.6574.4.2.1
- name: upsInfoAlarm
oid: 1.3.6.1.4.1.6574.4.2.2
type: DisplayString
help: UPS alarms - 1.3.6.1.4.1.6574.4.2.2
- name: upsInfoTime
oid: 1.3.6.1.4.1.6574.4.2.3
type: DisplayString
help: Internal UPS clock time - 1.3.6.1.4.1.6574.4.2.3
- name: upsInfoDate
oid: 1.3.6.1.4.1.6574.4.2.4
type: DisplayString
help: Internal UPS clock date - 1.3.6.1.4.1.6574.4.2.4
- name: upsInfoModel
oid: 1.3.6.1.4.1.6574.4.2.5
type: DisplayString
help: UPS model - 1.3.6.1.4.1.6574.4.2.5
- name: upsInfoMfrName
oid: 1.3.6.1.4.1.6574.4.2.6.1
type: DisplayString
help: UPS manufacturer - 1.3.6.1.4.1.6574.4.2.6.1
- name: upsInfoMfrDate
oid: 1.3.6.1.4.1.6574.4.2.6.2
type: DisplayString
help: UPS manufacturing date - 1.3.6.1.4.1.6574.4.2.6.2
- name: upsInfoSerial
oid: 1.3.6.1.4.1.6574.4.2.7
type: DisplayString
help: UPS serial number - 1.3.6.1.4.1.6574.4.2.7
- name: upsInfoVendorID
oid: 1.3.6.1.4.1.6574.4.2.8
type: DisplayString
help: Vendor ID for USB devices - 1.3.6.1.4.1.6574.4.2.8
- name: upsInfoProductID
oid: 1.3.6.1.4.1.6574.4.2.9
type: DisplayString
help: Product ID for USB devices - 1.3.6.1.4.1.6574.4.2.9
- name: upsInfoFirmwareName
oid: 1.3.6.1.4.1.6574.4.2.10.1
type: DisplayString
help: UPS firmware - 1.3.6.1.4.1.6574.4.2.10.1
- name: upsInfoFirmwareAux
oid: 1.3.6.1.4.1.6574.4.2.10.2
type: DisplayString
help: Auxiliary device firmware - 1.3.6.1.4.1.6574.4.2.10.2
- name: upsInfoTemperature
oid: 1.3.6.1.4.1.6574.4.2.11
type: Float
help: UPS temperature (degrees C) - 1.3.6.1.4.1.6574.4.2.11
- name: upsInfoLoadValue
oid: 1.3.6.1.4.1.6574.4.2.12.1
type: Float
help: Load on UPS (percent) - 1.3.6.1.4.1.6574.4.2.12.1
- name: upsInfoLoadHigh
oid: 1.3.6.1.4.1.6574.4.2.12.2
type: Float
help: Load when UPS switches to overload condition (OVER) (percent) - 1.3.6.1.4.1.6574.4.2.12.2
- name: upsInfoID
oid: 1.3.6.1.4.1.6574.4.2.13
type: DisplayString
help: UPS system identifier - 1.3.6.1.4.1.6574.4.2.13
- name: upsInfoDelayStart
oid: 1.3.6.1.4.1.6574.4.2.14.1
type: gauge
help: Interval to wait before restarting the load (seconds) - 1.3.6.1.4.1.6574.4.2.14.1
- name: upsInfoDelayReboot
oid: 1.3.6.1.4.1.6574.4.2.14.2
type: gauge
help: Interval to wait before rebooting the UPS (seconds) - 1.3.6.1.4.1.6574.4.2.14.2
- name: upsInfoDelayShutdown
oid: 1.3.6.1.4.1.6574.4.2.14.3
type: gauge
help: Interval to wait after shutdown with delay command (seconds) - 1.3.6.1.4.1.6574.4.2.14.3
- name: upsInfoTimerStart
oid: 1.3.6.1.4.1.6574.4.2.15.1
type: gauge
help: Time before the load will be started (seconds) - 1.3.6.1.4.1.6574.4.2.15.1
- name: upsInfoTimerReboot
oid: 1.3.6.1.4.1.6574.4.2.15.2
type: gauge
help: Time before the load will be rebooted (seconds) - 1.3.6.1.4.1.6574.4.2.15.2
- name: upsInfoTimerShutdown
oid: 1.3.6.1.4.1.6574.4.2.15.3
type: gauge
help: Time before the load will be shutdown (seconds) - 1.3.6.1.4.1.6574.4.2.15.3
- name: upsInfoTestInterval
oid: 1.3.6.1.4.1.6574.4.2.16.1
type: gauge
help: Interval between self tests - 1.3.6.1.4.1.6574.4.2.16.1
- name: upsInfoTestResult
oid: 1.3.6.1.4.1.6574.4.2.16.2
type: DisplayString
help: Results of last self test - 1.3.6.1.4.1.6574.4.2.16.2
- name: upsInfoDisplayLanguage
oid: 1.3.6.1.4.1.6574.4.2.17
type: DisplayString
help: Language to use on front panel - 1.3.6.1.4.1.6574.4.2.17
- name: upsInfoContacts
oid: 1.3.6.1.4.1.6574.4.2.18
type: DisplayString
help: UPS external contact sensors - 1.3.6.1.4.1.6574.4.2.18
- name: upsInfoEffciency
oid: 1.3.6.1.4.1.6574.4.2.19
type: gauge
help: Efficiency of the UPS (ratio of the output current on the input current)
(percent) - 1.3.6.1.4.1.6574.4.2.19
- name: upsInfoPowerValue
oid: 1.3.6.1.4.1.6574.4.2.20.1
type: Float
help: Current value of apparent power (Volt-Amps) - 1.3.6.1.4.1.6574.4.2.20.1
- name: upsInfoPowerNominal
oid: 1.3.6.1.4.1.6574.4.2.20.2
type: Float
help: Nominal value of apparent power (Volt-Amps) - 1.3.6.1.4.1.6574.4.2.20.2
- name: upsInfoRealPowerValue
oid: 1.3.6.1.4.1.6574.4.2.21.1
type: Float
help: Current value of real power (Watts) - 1.3.6.1.4.1.6574.4.2.21.1
- name: upsInfoRealPowerNominal
oid: 1.3.6.1.4.1.6574.4.2.21.2
type: Float
help: Nominal value of real power (Watts) - 1.3.6.1.4.1.6574.4.2.21.2
- name: upsInfoBeeperStatus
oid: 1.3.6.1.4.1.6574.4.2.22
type: DisplayString
help: UPS beeper status (enabled, disabled or muted) - 1.3.6.1.4.1.6574.4.2.22
- name: upsInfoType
oid: 1.3.6.1.4.1.6574.4.2.23
type: DisplayString
help: UPS type - 1.3.6.1.4.1.6574.4.2.23
- name: upsInfoWatchdogStatus
oid: 1.3.6.1.4.1.6574.4.2.24
type: DisplayString
help: UPS watchdog status (enabled or disabled) - 1.3.6.1.4.1.6574.4.2.24
- name: upsInfoStartAuto
oid: 1.3.6.1.4.1.6574.4.2.25.1
type: DisplayString
help: UPS starts when mains is (re)applied - 1.3.6.1.4.1.6574.4.2.25.1
- name: upsInfoStartBattery
oid: 1.3.6.1.4.1.6574.4.2.25.2
type: DisplayString
help: Allow to start UPS from battery - 1.3.6.1.4.1.6574.4.2.25.2
- name: upsInfoStartReboot
oid: 1.3.6.1.4.1.6574.4.2.25.3
type: DisplayString
help: UPS coldstarts from battery (enabled or disabled) - 1.3.6.1.4.1.6574.4.2.25.3
- name: upsBatteryChargeValue
oid: 1.3.6.1.4.1.6574.4.3.1.1
type: Float
help: Battery charge - 1.3.6.1.4.1.6574.4.3.1.1
- name: upsBatteryChargeLow
oid: 1.3.6.1.4.1.6574.4.3.1.2
type: Float
help: Remaining battery level when UPS switches to LB (percent) - 1.3.6.1.4.1.6574.4.3.1.2
- name: upsBatteryChargeRestart
oid: 1.3.6.1.4.1.6574.4.3.1.3
type: Float
help: Minimum battery level for UPS restart after power-off - 1.3.6.1.4.1.6574.4.3.1.3
- name: upsBatteryChargeWarning
oid: 1.3.6.1.4.1.6574.4.3.1.4
type: Float
help: Battery level when UPS switches to Warning state (percent) - 1.3.6.1.4.1.6574.4.3.1.4
- name: upsBatteryVoltageValue
oid: 1.3.6.1.4.1.6574.4.3.2.1
type: Float
help: The magnitude of the present battery voltage. - 1.3.6.1.4.1.6574.4.3.2.1
- name: upsBatteryVoltageNominal
oid: 1.3.6.1.4.1.6574.4.3.2.2
type: Float
help: Nominal battery voltage. - 1.3.6.1.4.1.6574.4.3.2.2
- name: upsBatteryVoltageLow
oid: 1.3.6.1.4.1.6574.4.3.2.3
type: Float
help: Minimum battery voltage, that triggers FSD status . - 1.3.6.1.4.1.6574.4.3.2.3
- name: upsBatteryVoltageHigh
oid: 1.3.6.1.4.1.6574.4.3.2.4
type: Float
help: Maximum battery voltage (Ie battery.charge = 100). - 1.3.6.1.4.1.6574.4.3.2.4
- name: upsBatteryCapacity
oid: 1.3.6.1.4.1.6574.4.3.3
type: Float
help: Battery capacity (Ah) - 1.3.6.1.4.1.6574.4.3.3
- name: upsBatteryCurrent
oid: 1.3.6.1.4.1.6574.4.3.4
type: Float
help: The present battery current. - 1.3.6.1.4.1.6574.4.3.4
- name: upsBatteryTemperature
oid: 1.3.6.1.4.1.6574.4.3.5
type: Float
help: The ambient temperature at or near the UPS Battery casing. - 1.3.6.1.4.1.6574.4.3.5
- name: upsBatteryRuntimeValue
oid: 1.3.6.1.4.1.6574.4.3.6.1
type: gauge
help: Battery runtime (seconds) - 1.3.6.1.4.1.6574.4.3.6.1
- name: upsBatteryRuntimeLow
oid: 1.3.6.1.4.1.6574.4.3.6.2
type: gauge
help: Remaining battery runtime when UPS switches to LB (seconds) - 1.3.6.1.4.1.6574.4.3.6.2
- name: upsBatteryRuntimeRestart
oid: 1.3.6.1.4.1.6574.4.3.6.3
type: gauge
help: Minimum battery runtime for UPS restart after power-off (seconds) - 1.3.6.1.4.1.6574.4.3.6.3
- name: upsBatteryAlarmThreshold
oid: 1.3.6.1.4.1.6574.4.3.7
type: DisplayString
help: Battery alarm threshold - 1.3.6.1.4.1.6574.4.3.7
- name: upsBatteryDate
oid: 1.3.6.1.4.1.6574.4.3.8
type: DisplayString
help: Battery change date - 1.3.6.1.4.1.6574.4.3.8
- name: upsBatteryMfrDate
oid: 1.3.6.1.4.1.6574.4.3.9
type: DisplayString
help: Battery manufacturing date - 1.3.6.1.4.1.6574.4.3.9
- name: upsBatteryPacks
oid: 1.3.6.1.4.1.6574.4.3.10
type: gauge
help: Number of battery packs - 1.3.6.1.4.1.6574.4.3.10
- name: upsBatteryPacksBad
oid: 1.3.6.1.4.1.6574.4.3.11
type: gauge
help: Number of bad battery packs - 1.3.6.1.4.1.6574.4.3.11
- name: upsBatteryType
oid: 1.3.6.1.4.1.6574.4.3.12
type: DisplayString
help: Battery chemistry - 1.3.6.1.4.1.6574.4.3.12
- name: upsBatteryProtection
oid: 1.3.6.1.4.1.6574.4.3.13
type: DisplayString
help: Prevent deep discharge of battery - 1.3.6.1.4.1.6574.4.3.13
- name: upsBatteryEnergySave
oid: 1.3.6.1.4.1.6574.4.3.14
type: DisplayString
help: Switch off when running on battery and no/low load - 1.3.6.1.4.1.6574.4.3.14
- name: upsInputVoltageValue
oid: 1.3.6.1.4.1.6574.4.4.1.1
type: Float
help: Input voltage - 1.3.6.1.4.1.6574.4.4.1.1
- name: upsInputVoltageMax
oid: 1.3.6.1.4.1.6574.4.4.1.2
type: Float
help: Maximum incoming voltage seen - 1.3.6.1.4.1.6574.4.4.1.2
- name: upsInputVoltageMin
oid: 1.3.6.1.4.1.6574.4.4.1.3
type: Float
help: Minimum incoming voltage seen - 1.3.6.1.4.1.6574.4.4.1.3
- name: upsInputVoltageNominal
oid: 1.3.6.1.4.1.6574.4.4.1.4
type: Float
help: Nominal input voltage - 1.3.6.1.4.1.6574.4.4.1.4
- name: upsInputVoltageExtend
oid: 1.3.6.1.4.1.6574.4.4.1.5
type: DisplayString
help: Extended input voltage range - 1.3.6.1.4.1.6574.4.4.1.5
- name: upsInputVoltageFault
oid: 1.3.6.1.4.1.6574.4.4.1.6
type: Float
help: Input voltage Fault - 1.3.6.1.4.1.6574.4.4.1.6
- name: upsInputTransferReason
oid: 1.3.6.1.4.1.6574.4.4.2.1
type: DisplayString
help: Reason for last transfer to battery - 1.3.6.1.4.1.6574.4.4.2.1
- name: upsInputTransferLow
oid: 1.3.6.1.4.1.6574.4.4.2.2
type: Float
help: Low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.2
- name: upsInputTransferHigh
oid: 1.3.6.1.4.1.6574.4.4.2.3
type: Float
help: High voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.3
- name: upsInputTransferLowMin
oid: 1.3.6.1.4.1.6574.4.4.2.4
type: Float
help: smallest settable low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.4
- name: upsInputTransferLowMax
oid: 1.3.6.1.4.1.6574.4.4.2.5
type: Float
help: greatest settable low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.5
- name: upsInputTransferHighMin
oid: 1.3.6.1.4.1.6574.4.4.2.6
type: Float
help: smallest settable high voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.6
- name: upsInputTransferHighMax
oid: 1.3.6.1.4.1.6574.4.4.2.7
type: Float
help: greatest settable high voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.7
- name: upsInputTransferBoostLow
oid: 1.3.6.1.4.1.6574.4.4.2.8
type: Float
help: Low voltage boosting transfer point - 1.3.6.1.4.1.6574.4.4.2.8
- name: upsInputTransferBoostHigh
oid: 1.3.6.1.4.1.6574.4.4.2.9
type: Float
help: High voltage boosting transfer point - 1.3.6.1.4.1.6574.4.4.2.9
- name: upsInputTransferTrimLow
oid: 1.3.6.1.4.1.6574.4.4.2.10
type: Float
help: Low voltage trimming transfer point - 1.3.6.1.4.1.6574.4.4.2.10
- name: upsInputTransferTrimHigh
oid: 1.3.6.1.4.1.6574.4.4.2.11
type: Float
help: High voltage trimming transfer point - 1.3.6.1.4.1.6574.4.4.2.11
- name: upsInputSensitivity
oid: 1.3.6.1.4.1.6574.4.4.3
type: DisplayString
help: Input power sensitivity - 1.3.6.1.4.1.6574.4.4.3
- name: upsInputQuality
oid: 1.3.6.1.4.1.6574.4.4.4
type: DisplayString
help: Input power quality - 1.3.6.1.4.1.6574.4.4.4
- name: upsInputCurrentValue
oid: 1.3.6.1.4.1.6574.4.4.5.1
type: Float
help: Input current (A) - 1.3.6.1.4.1.6574.4.4.5.1
- name: upsInputCurrentNominal
oid: 1.3.6.1.4.1.6574.4.4.5.2
type: Float
help: Nominal input current (A) - 1.3.6.1.4.1.6574.4.4.5.2
- name: upsInputFrequencyValue
oid: 1.3.6.1.4.1.6574.4.4.6.1
type: Float
help: Input line frequency (Hz) - 1.3.6.1.4.1.6574.4.4.6.1
- name: upsInputFrequencyNominal
oid: 1.3.6.1.4.1.6574.4.4.6.2
type: Float
help: Nominal input line frequency (Hz) - 1.3.6.1.4.1.6574.4.4.6.2
- name: upsInputFrequencyLow
oid: 1.3.6.1.4.1.6574.4.4.6.3
type: Float
help: Input line frequency low (Hz) - 1.3.6.1.4.1.6574.4.4.6.3
- name: upsInputFrequencyHigh
oid: 1.3.6.1.4.1.6574.4.4.6.4
type: Float
help: Input line frequency high (Hz) - 1.3.6.1.4.1.6574.4.4.6.4
- name: upsInputFrequencyExtend
oid: 1.3.6.1.4.1.6574.4.4.6.5
type: DisplayString
help: Extended input frequency range - 1.3.6.1.4.1.6574.4.4.6.5
- name: upsOutputVoltageValue
oid: 1.3.6.1.4.1.6574.4.5.1.1
type: Float
help: Output voltage (V) - 1.3.6.1.4.1.6574.4.5.1.1
- name: upsOutputVoltageNominal
oid: 1.3.6.1.4.1.6574.4.5.1.2
type: Float
help: Nominal output voltage (V) - 1.3.6.1.4.1.6574.4.5.1.2
- name: upsOutputFrequencyValue
oid: 1.3.6.1.4.1.6574.4.5.2.1
type: Float
help: Output frequency (Hz) - 1.3.6.1.4.1.6574.4.5.2.1
- name: upsOutputFrequencyNominal
oid: 1.3.6.1.4.1.6574.4.5.2.2
type: Float
help: Nominal output frequency (Hz) - 1.3.6.1.4.1.6574.4.5.2.2
- name: upsOutputCurrentValue
oid: 1.3.6.1.4.1.6574.4.5.3.1
type: Float
help: Output current (A) - 1.3.6.1.4.1.6574.4.5.3.1
- name: upsOutputCurrentNominal
oid: 1.3.6.1.4.1.6574.4.5.3.2
type: Float
help: Nominal output current (A) - 1.3.6.1.4.1.6574.4.5.3.2
- name: upsAmbientTemperatureValue
oid: 1.3.6.1.4.1.6574.4.6.1.1
type: Float
help: Ambient temperature (degrees C) - 1.3.6.1.4.1.6574.4.6.1.1
- name: upsAmbientTemperatureAlarm
oid: 1.3.6.1.4.1.6574.4.6.1.2
type: DisplayString
help: Temperature alarm (enabled/disabled) - 1.3.6.1.4.1.6574.4.6.1.2
- name: upsAmbientTemperatureHigh
oid: 1.3.6.1.4.1.6574.4.6.1.3
type: Float
help: Temperature threshold high (degrees C) - 1.3.6.1.4.1.6574.4.6.1.3
- name: upsAmbientTemperatureLow
oid: 1.3.6.1.4.1.6574.4.6.1.4
type: Float
help: Temperature threshold low (degrees C) - 1.3.6.1.4.1.6574.4.6.1.4
- name: upsAmbientTemperatureMax
oid: 1.3.6.1.4.1.6574.4.6.1.5
type: Float
help: Maximum temperature seen (degrees C) - 1.3.6.1.4.1.6574.4.6.1.5
- name: upsAmbientTemperatureMin
oid: 1.3.6.1.4.1.6574.4.6.1.6
type: Float
help: Minimum temperature seen (degrees C) - 1.3.6.1.4.1.6574.4.6.1.6
- name: upsAmbientHumidityValue
oid: 1.3.6.1.4.1.6574.4.6.2.1
type: Float
help: Ambient relative humidity (percent) - 1.3.6.1.4.1.6574.4.6.2.1
- name: upsAmbientHumidityAlarm
oid: 1.3.6.1.4.1.6574.4.6.2.2
type: DisplayString
help: Relative humidity alarm (enabled/disabled) - 1.3.6.1.4.1.6574.4.6.2.2
- name: upsAmbientHumidityHigh
oid: 1.3.6.1.4.1.6574.4.6.2.3
type: Float
help: Relative humidity threshold high (percent) - 1.3.6.1.4.1.6574.4.6.2.3
- name: upsAmbientHumidityLow
oid: 1.3.6.1.4.1.6574.4.6.2.4
type: Float
help: Relative humidity threshold low (percent) - 1.3.6.1.4.1.6574.4.6.2.4
- name: upsAmbientHumidityMax
oid: 1.3.6.1.4.1.6574.4.6.2.5
type: Float
help: Maximum relative humidity seen (percent) - 1.3.6.1.4.1.6574.4.6.2.5
- name: upsAmbientHumidityMin
oid: 1.3.6.1.4.1.6574.4.6.2.6
type: Float
help: Minimum relative humidity seen (percent) - 1.3.6.1.4.1.6574.4.6.2.6
- name: upsDriverName
oid: 1.3.6.1.4.1.6574.4.7.1
type: DisplayString
help: Driver name - 1.3.6.1.4.1.6574.4.7.1
- name: upsDriverVersion
oid: 1.3.6.1.4.1.6574.4.7.2
type: DisplayString
help: Driver version (NUT release) - 1.3.6.1.4.1.6574.4.7.2
- name: upsDriverVersionData
oid: 1.3.6.1.4.1.6574.4.7.3
type: DisplayString
help: Driver version data - 1.3.6.1.4.1.6574.4.7.3
- name: upsDriverVersionInternal
oid: 1.3.6.1.4.1.6574.4.7.4
type: DisplayString
help: Internal driver version (if tracked separately) - 1.3.6.1.4.1.6574.4.7.4
- name: upsDriverPollInterval
oid: 1.3.6.1.4.1.6574.4.7.5
type: gauge
help: Poll interval setup in configuration file - 1.3.6.1.4.1.6574.4.7.5
- name: upsDriverPort
oid: 1.3.6.1.4.1.6574.4.7.6
type: DisplayString
help: Port setup in configuration file - 1.3.6.1.4.1.6574.4.7.6
- name: upsDriverPollFrequency
oid: 1.3.6.1.4.1.6574.4.7.7
type: gauge
help: Poll frequency - 1.3.6.1.4.1.6574.4.7.7
- name: upsDriverProductID
oid: 1.3.6.1.4.1.6574.4.7.8
type: DisplayString
help: Product ID - 1.3.6.1.4.1.6574.4.7.8
- name: upsDriverSnmpVersion
oid: 1.3.6.1.4.1.6574.4.7.9
type: DisplayString
help: Snmp version - 1.3.6.1.4.1.6574.4.7.9
- name: upsServerInfo
oid: 1.3.6.1.4.1.6574.4.8.1
type: DisplayString
help: Server information - 1.3.6.1.4.1.6574.4.8.1
- name: upsServerVersion
oid: 1.3.6.1.4.1.6574.4.8.2
type: DisplayString
help: Server version - 1.3.6.1.4.1.6574.4.8.2
- name: diskSMARTInfoIndex
oid: 1.3.6.1.4.1.6574.5.1.1.1
type: gauge
help: SMART info index - 1.3.6.1.4.1.6574.5.1.1.1
indexes:
- labelname: diskSMARTInfoIndex
type: gauge
- name: diskSMARTInfoDevName
oid: 1.3.6.1.4.1.6574.5.1.1.2
type: DisplayString
help: SMART info device name - 1.3.6.1.4.1.6574.5.1.1.2
indexes:
- labelname: diskSMARTInfoIndex
type: gauge
- name: diskSMARTAttrName
oid: 1.3.6.1.4.1.6574.5.1.1.3
type: DisplayString
help: SMART attribute name - 1.3.6.1.4.1.6574.5.1.1.3
indexes:
- labelname: diskSMARTInfoIndex
type: gauge
- name: diskSMARTAttrId
oid: 1.3.6.1.4.1.6574.5.1.1.4
type: gauge
help: SMART attribute ID - 1.3.6.1.4.1.6574.5.1.1.4
indexes:
- labelname: diskSMARTInfoIndex
type: gauge
- name: diskSMARTAttrCurrent
oid: 1.3.6.1.4.1.6574.5.1.1.5
type: gauge
help: SMART attribute current value - 1.3.6.1.4.1.6574.5.1.1.5
indexes:
- labelname: diskSMARTInfoIndex
type: gauge
- name: diskSMARTAttrWorst
oid: 1.3.6.1.4.1.6574.5.1.1.6
type: gauge
help: SMART attribute worst value - 1.3.6.1.4.1.6574.5.1.1.6
indexes:
- labelname: diskSMARTInfoIndex
type: gauge
- name: diskSMARTAttrThreshold
oid: 1.3.6.1.4.1.6574.5.1.1.7
type: gauge
help: SMART attribute threshold value - 1.3.6.1.4.1.6574.5.1.1.7
indexes:
- labelname: diskSMARTInfoIndex
type: gauge
- name: diskSMARTAttrRaw
oid: 1.3.6.1.4.1.6574.5.1.1.8
type: gauge
help: SMART attribute raw value - 1.3.6.1.4.1.6574.5.1.1.8
indexes:
- labelname: diskSMARTInfoIndex
type: gauge
- name: diskSMARTAttrStatus
oid: 1.3.6.1.4.1.6574.5.1.1.9
type: DisplayString
help: SMART attribute status - 1.3.6.1.4.1.6574.5.1.1.9
indexes:
- labelname: diskSMARTInfoIndex
type: gauge
- name: serviceInfoIndex
oid: 1.3.6.1.4.1.6574.6.1.1.1
type: gauge
help: Service info index - 1.3.6.1.4.1.6574.6.1.1.1
indexes:
- labelname: serviceInfoIndex
type: gauge
lookups:
- labels:
- serviceInfoIndex
labelname: serviceName
oid: 1.3.6.1.4.1.6574.6.1.1.2
type: DisplayString
- labels: []
labelname: serviceInfoIndex
- name: serviceName
oid: 1.3.6.1.4.1.6574.6.1.1.2
type: DisplayString
help: Service name - 1.3.6.1.4.1.6574.6.1.1.2
indexes:
- labelname: serviceInfoIndex
type: gauge
lookups:
- labels:
- serviceInfoIndex
labelname: serviceName
oid: 1.3.6.1.4.1.6574.6.1.1.2
type: DisplayString
- labels: []
labelname: serviceInfoIndex
- name: serviceUsers
oid: 1.3.6.1.4.1.6574.6.1.1.3
type: gauge
help: Number of users using this service - 1.3.6.1.4.1.6574.6.1.1.3
indexes:
- labelname: serviceInfoIndex
type: gauge
lookups:
- labels:
- serviceInfoIndex
labelname: serviceName
oid: 1.3.6.1.4.1.6574.6.1.1.2
type: DisplayString
- labels: []
labelname: serviceInfoIndex